miniPV-Series Automatic Viscometer with VISCPRO
®
Instruction & Operation Manual
Version 1.a— January, 2011; CANNON
®
Instrument Company
2139 High Tech Road • State College, PA 16803 • USA
102
g. If you would like to include a header at the beginning of the
analysis, click the Header button and add the desired text string
via the keyboard. Format the entry as desired using the Carriage
Return (CR) and Line Feed (LF) options as necessary to indicate
line breaks. Then click OK.
Adding a footer
h. If you would like to include a footer at the end of the analysis,
click the Footer button and add the desired text string via the
keyboard. Format the entry as desired using the Space, Carriage
Return (CR) and Line Feed (LF) options. Then click OK.
(Space—Inserts a blank space, CR—Inserts a carriage return
code, and LF—Inserts a line feed code)
NOTE
If you have selected the Dynamic Update option using the Date tab
options, the footer will not be sent until the analysis window is closed.
8. When you have completed the configuration, click OK. Serial data
will be routed to the appropriate ports/files and you will be prompted
to save the configuration.
9. If you do not wish to save the configuration, click No. The analysis
will be displayed and the data will be sent to the selected ports. If you
wish to save the configuration, click Yes. The Save Configuration
window will appear. Type the name of the new configuration in the
Save As: field. Or double-click the name of a preexisting configura-
tion in the Existing Configurations list box to replace the existing
configuration with the new configuration settings. Then click OK.
The saved analysis will be displayed using the selected configuration
settings, and the data will be sent to the selected ports.
NOTES
You may click Cancel from the Save Configuration window to exit without
saving configuration changes.
The Port Output Analysis cannot be reconfigured. This avoids duplication
of output data for collection devices your facility may have in place. You
may still view configuration options for a displayed analysis by selecting
Configure Analysis from the Analyses menu and choosing the correct
analysis.
Re-sending export data
To re-send Port Output Analysis data for a displayed analysis, first save
the analysis by clicking Analyses/Save Configuration, selecting the desired
analysis, typing the analysis name in the Save As: list box and clicking
OK. Then close the Port Output Analysis window and re-select Port Output
Analysis by clicking Analyses/View Analysis from the primary menu